multiMAUS Firmware V1.02
For the majority of the multiMAUS users there is no reason to update their multiMAUS with this firmware. The version V1.00 that was delivered since the beginning of production runs properly and stabil.
Just in case problems occur in the following circumstances you should upgrade to the new version:
- To address the F13 and the F20 decoder functions (as long as your decoder supports those and they are not occupied yet).
- Your problem is to programm generic decoder models.
- You are operating more than 10 feedback modules 10787.
- During the programming in POM-mode with the LENZ control station the error message "ERR1" appears on the multiMAUS.
- Despite that there are no feedback contacts activated, blocks in the Rocomotion light up sporadically in pink (occupied).
If one of these points is affecting your operation we recommend the update V1.02.
Note:
- Your multiMAUS settings as well as the entry in the locomotive databank will still be available after the update.
- Under the menu of the multiMAUS you can find the current version (for example about the V 1-00): "Settings" - sub menu "Infos" - sub menu "Sofware".
- multiMAUS users who do not have a Rocomotion Interface 10785 available can send it to the customer service department via the specialized dealers.
Here you can download the update files:
multiMAUS Update V1.02 / 585 KB
Manual for the multiMAUS - update
Needed are the Interface 10785 as well as the two files MultimausUpdate.EXE and MMTestLib.DLL which should be stored in the same folder. Connect the
multiMAUS that is supposed to be updated to the master port of the amplifyer 10761/10764. Connect
ROCOMOTION 10785 to the slave port.
Important information:
- Other components that are still connected to the slave port can remain connected however they will not be functional during the update.
- Do not start the ROCOMOTION software or the training programme or if so only in offline mode.
- Do not interrupt the update by unplugging the multiMAUS, the ROCOMOTION or other connected components. In case you did, the multiMAUS will display “Err 99”. You will have to start the update all over again and finish it to make the multiMAUS functional again.
- The firmware-update is available in the standard languages (German, English, French, Italian). If your multiMAUS was delivered with a different language please contact your specialized dealer.
By double-clicking on "MultiMaus Update" the file opens.
The following window appears:

This setting has to correspond with the interface of the computer with which the ROCOMOTION is operated!
Now you can press the "start" button.
The update is starting.

Once the update is complete the following window will appear:

If an additional multiMOUSE is to be updated the process can be repeated after another multiMOUSE has been connected.